Contact Us: 423.870.5558
msi@metroservicesinc.com

Products

Flame Monitoring System

Metro Services, Incorporated carries a full line of commercial and industrial flame safeguard controls. If you have an application that needs a flame safeguard, then we will have a product that fits your needs.

ECLIPSE

flame-monitoring-system-img1

Eclipse Combustion Bi-Flame

The Eclipse Combustion Bi-Flame controls the start-up sequence and monitors the flame of two individual gas, oil or combination gas/oil burners. Bi-Flame controls two flames as a single burner.

Available with valve proving system sequence, proof of valve closure testing, history logging and other optional features. Registered users who are logged in can view more.

Features:

  • UL recognized, FM approved and CSA certified
  • Microcomputer based system
  • 0-12 VDC flame signal test ports conveniently located on front of unit
  • Monitors up to two burners
  • Flame sensor module for ultraviolet and/or flame rod
  • DIP switches for timing functions and system configuration
  • Internal safe-start diagnostic testing

flame-monitoring-system-img2

Eclipse Combustion Multi-Flame

The Eclipse Combustion Multi-Flame controls the start-up sequence and monitors the flame of up to 20 gas, oil or combination gas/oil burners connected to a common valve train.

Available with valve proving system sequence, proof of valve closure testing, history logging and other optional features. Registered users who are logged in can view more details by downloading Bulletin 820 from the technical documents section below.

Features:

  • UL recognized, FM approved and CSA certified
  • Microcomputer based system
  • Plug-in to the motherboard modular design for the following parts:
    • Power supply
    • Relay module
  • Logic Module Eclipse Peek-a-Flame sensor modules with 0-12 VDC signal test ports
  • Monitors up to 20 burners with expansion board option. One down, all out logic
  • Flame sensor module for ultraviolet and/or flame rod
  • DIP switches for timing functions and system configuration
  • Internal safe-start diagnostic testing
  • Test mode for pilot flame adjustments

flame-monitoring-system-img3

Eclipse Combustion Veri-Flame

The Eclipse Combustion Veri-Flame single burner monitoring system controls the start-up sequence and monitors the flame of single gas, oil or combination gas/oil burners. There are three different models to the Veri-Flame Line: No purge, Purge, Modulation.

Each model features field selectable trial for ignition (TFI). Each model is also available for use with four types of flame sensor: Ultraviolet (UV), Self-check UV, Infrared (IR) and Solid State UV/IR, Flame Rod.

Registered users who are logged in can download Instruction Manual 818 for detailed information on this device.

HONEYWELL

flame-monitoring-system-img4

Honeywell RM7800 Flame Monitoring System

Microprocessor-based integrated single-burner control. Replaces more than 400 Honeywell and competitive types. Provides enhanced safety. Comprehensive diagnostics. Communication and networking capabilities.

flame-monitoring-system-img5

Honeywell UV Scanner Flame Monitoring System

Choice of four models of ultraviolet flame detectors to meet a variety of application requirements Solid-state accuracy and reliability. Dynamic self-check flame detectors available for systems with long run-time Sense flames difficult to detect Provide mounting flexibility.

PCI

flame-monitoring-system-img6

Protectofier 6642 – Combustion Safeguards Flame Monitoring System

FORM 6642VA

Basic combustion safeguard model

FORM 6642VB

Breaker – lockout switch model
Required for automatic lighted installations. System “latches out” after failure to light within ignition trial time and cannot attempt restart until switch is manually reset.
Standard ignition trial time is 15 seconds. Also available in 10-second and 5-second trial time.

FORM 6642VL

Load relay – included for all multi-burner models

FORM 6642VT

Timofier model plugin, fixed time assembly.
The timofier provides purge time and ignition trial time. The ignition trial time is deducted from the motor time cycle (1/2, 1, 1-1/4, 2, 3, 4, and 6 minutes available for manual and automatic models; 10 minutes for manual model only) to purge the time.

Standard ignition trial time is 15 seconds. Also available in 10-second and 5-second trial time. Specify both purge and ignition times. Purge time shall allow system to have a minimum of four fresh air changes.

FORM 6642VBL

Combines features of Breaker and Load relay models described above.

FORM 6642VBT

Combines features of Breaker and Timofier models described above.

FORM 6642VLT

Combines features of Load relay and Timofier models described above.

FORM 6642VBLT

Combines features of Breaker, Load relay, and Timofier models described above.

flame-monitoring-system-img7

Protectofier 7256 – Combustion Safeguards Flame Monitoring System

FORM 7256-AH/AHE

Basic manual model
“E” indicates enclosed model.

FORM 7256-B/BE

Manual or automatic operation
Recycle on flame failure automatic. Select ignition trial timing cycle: 15 sec.(standard), 5 sec. or 10 sec.
“E” indicates enclosed model.

FORM 7256-BH/BHE

“H” indicates flame failure alarm
Recycle on flame failure automatic. Select ignition trial timing cycle: 15 sec.(standard), 5 sec. or 10 sec.
“E” indicates enclosed model.

FORM 7256-BNRE/BNRHE

“NR” indicates automatic models with additional relay to prevent relight attempt on flame failure. Select ignition trial timing cycle: 15 sec.(standard), 5 sec. or 10 sec.
“E” indicates enclosed model.

FORM 7256-BTNRE/BTNRHE

“T” indicates plug-in “SST” purge timer provided for fixed pre-purged cycle. Select purge cycle: 15, 30, 60 or 90 sec. Select ignition trial timing cycle: 15 sec.(standard), 5 sec. or 10 sec.
“E” indicates enclosed model.

flame-monitoring-system-img8

P-C II – Ultra-violet Scanner

Detects any flame which contains ultra-violet.

P-C II

Basic model. Provided with an electrical connector for flexible metal conduit (3/8″ max.)

P-C II W

Provided with 1/2″ straight liquid-tite electrical connector.

P-C II WRA

Provided with a 1/2″ right angle liquid-tite electrical connector.

flame-monitoring-system-img9

Tele-Fault II 8966 – First-outage Fault Finder

Unequalled reliability and operating savings for monitoring equipment in heating and processing systems. Monitors up to 8 read-out positions.

Features:

  • Single Wire Connections
  • No Additional Relays
  • Compact Design 1/4 Din Size
  • Start-Up Status Display
  • First-Outage Readout
  • Power Interruption Indicator
  • Lights and Pushbuttons

flame-monitoring-system-img10

Estro Microprocessor Flame Supervisor

The ESTRO flame relays are innovative microprocessor based flame control relay for single burners units. They provide complete automation on the ignition and flame control of burner systems. They can be interfaced via a current loop to a computer or a PLC.

flame-monitoring-system-img11

Microscan Microprocessor Compact Control System

The MICROSCAN is a very compact PLC for the supervision and memorization of operation and safety switches of combustion equipment. They provide the usual functions: Alarm bypass / Alarm silence / Reset / Lamp test.

flame-monitoring-system-img12

Sens-A-Flame Electronic Flame Monitoring

The Sens-A-Flame is an electronic flame monitoring device that offers continuous surveillance of flames, detects the flame out, triggers a warning and shuts down the entire combustion system. It is designed for use with single or multiple burner installations. It includes many built-in features, solid state components for long life and plug-in modules for easy maintenance. They use ultraviolet or flame rod detectors.

flame-monitoring-system-img13

Pyronics Ultraviolet Scanners

The Pyronics UV Scanners are compact, reliable sensing units designed for use with the Sens-A-Flame. They are easy to install. They are built in weather resistant cast Aluminum enclosure.