Chattanooga Flame Safeguard and Flame Monitoring Systems

Metro Services, Incorporated carries a full line of commercial and industrial flame safeguard controls. If you have an application that needs a flame safeguard, then we will have a product that fits your needs.

SIEMENS

Siemens Flame Safeguard

Siemens Flame Safeguard LME7

Siemens LME7 Flame safeguard sets a new standard for flexible, cost-effective burner supervision. Ease of installation, programming and commissioning are incorporated into a reliable, field-proven control. The LME7 offers flexibility not found in competitive burner control units, at a very attractive price.

  • UV scanner and flame rod sensor inputs
  • Programmable purge times, safety times, and pilot operation
  • Integral LED display for easy diagnostics
  • Globally approved – UL, FM, CSA, and CE

Siemens Burner Controls

Siemens Burner Controls LME7

The burner control LME7 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.

LME7 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation. The fuel-air ratio can be set either via an air damper actuator – acting on mechanical or pneumatic ratio control – or via pulse width modulated fans and pneumatic ratio control.

Features:

  • Undervoltage detection
  • Electrical remote reset facility
  • Accurate control times thanks to digital signal handling
  • Multicolor indication of fault status and operating state messages
  • Air pressure supervision with function check of air pressure switch during start and operation
  • Repetition limitation
  • Controlled intermittent operation after max. 24 hours of continuous operation (can be parameterized via parameter 239) (depending on type of program module PME7)
  • BCI
  • Unit parameter adjustable either via display or PC software ACS410
  • Connection for program module PME

Siemens Burner Controls

Siemens Burner Controls LFL and LAL

Siemens LFL and LAL burner controls provide burner sequencing and flame monitoring for the supervision of individual gas, oil, or dual-fueled burners. With an incomparable record for safety and reliability, the economical LFL continues to be one of the most popular, globally approved flame safeguard controls.

Siemens Flame Detector

Siemens Flame Detector QRA4

UV flame detector for use with burner controls from Siemens for the supervision of gas or oil flames. The flame detector is used for the supervision of gas flames, yellow- or blue-burning oil flames and for ignition spark proving in intermittent operation.

Siemens LMV5 Linkageless Burner Management System

Siemens LMV5 Linkageless Burner Management System

The LMV5 Linkageless Burner Management System sets the standard high – from easy installation, programming and commissioning to reliable, proven control. With the LMV5, Siemens forges new ground delivering a fully integrated system that is not only easy to install and use, but also provides improved burner performance and efficiency and ensures safe operation.

  • Fuel to air ratio curve can easily be adjusted at any point in the firing rate
  • 15 programmable points, with 4 independent positions including pre-purge, ignition, post-purge and standby
  • User-friendly menu system for fast programming and commissioning
  • Worldwide approvals and technical support

HONEYWELL

flame-monitoring-system-img4

Honeywell RM7800 Flame Monitoring System

Microprocessor-based integrated single-burner control. Replaces more than 400 Honeywell and competitive types. Provides enhanced safety. Comprehensive diagnostics. Communication and networking capabilities.

flame-monitoring-system-img5

Honeywell UV Scanner Flame Monitoring System

Choice of four models of ultraviolet flame detectors to meet a variety of application requirements Solid-state accuracy and reliability. Dynamic self-check flame detectors available for systems with long run-time Sense flames difficult to detect Provide mounting flexibility.

PCI

flame-monitoring-system-img6

Protectofier 6642 – Combustion Safeguards Flame Monitoring System

FORM 6642VA

Basic combustion safeguard model

FORM 6642VB

Breaker – lockout switch model
Required for automatic lighted installations. System “latches out” after failure to light within ignition trial time and cannot attempt restart until switch is manually reset.
Standard ignition trial time is 15 seconds. Also available in 10-second and 5-second trial time.

FORM 6642VL

Load relay – included for all multi-burner models

FORM 6642VT

Timofier model plugin, fixed time assembly.
The timofier provides purge time and ignition trial time. The ignition trial time is deducted from the motor time cycle (1/2, 1, 1-1/4, 2, 3, 4, and 6 minutes available for manual and automatic models; 10 minutes for manual model only) to purge the time.

Standard ignition trial time is 15 seconds. Also available in 10-second and 5-second trial time. Specify both purge and ignition times. Purge time shall allow system to have a minimum of four fresh air changes.

FORM 6642VBL

Combines features of Breaker and Load relay models described above.

FORM 6642VBT

Combines features of Breaker and Timofier models described above.

FORM 6642VLT

Combines features of Load relay and Timofier models described above.

FORM 6642VBLT

Combines features of Breaker, Load relay, and Timofier models described above.

flame-monitoring-system-img7

Protectofier 7256 – Combustion Safeguards Flame Monitoring System

FORM 7256-AH/AHE

Basic manual model
“E” indicates enclosed model.

FORM 7256-B/BE

Manual or automatic operation
Recycle on flame failure automatic. Select ignition trial timing cycle: 15 sec.(standard), 5 sec. or 10 sec.
“E” indicates enclosed model.

FORM 7256-BH/BHE

“H” indicates flame failure alarm
Recycle on flame failure automatic. Select ignition trial timing cycle: 15 sec.(standard), 5 sec. or 10 sec.
“E” indicates enclosed model.

FORM 7256-BNRE/BNRHE

“NR” indicates automatic models with additional relay to prevent relight attempt on flame failure. Select ignition trial timing cycle: 15 sec.(standard), 5 sec. or 10 sec.
“E” indicates enclosed model.

FORM 7256-BTNRE/BTNRHE

“T” indicates plug-in “SST” purge timer provided for fixed pre-purged cycle. Select purge cycle: 15, 30, 60 or 90 sec. Select ignition trial timing cycle: 15 sec.(standard), 5 sec. or 10 sec.
“E” indicates enclosed model.

flame-monitoring-system-img8

P-C II – Ultra-violet Scanner

Detects any flame which contains ultra-violet.

P-C II

Basic model. Provided with an electrical connector for flexible metal conduit (3/8″ max.)

P-C II W

Provided with 1/2″ straight liquid-tite electrical connector.

P-C II WRA

Provided with a 1/2″ right angle liquid-tite electrical connector.

flame-monitoring-system-img9

Tele-Fault II 8966 – First-outage Fault Finder

Unequalled reliability and operating savings for monitoring equipment in heating and processing systems. Monitors up to 8 read-out positions.

Features:

  • Single Wire Connections
  • No Additional Relays
  • Compact Design 1/4 Din Size
  • Start-Up Status Display
  • First-Outage Readout
  • Power Interruption Indicator
  • Lights and Pushbuttons

flame-monitoring-system-img10

Estro Microprocessor Flame Supervisor

The ESTRO flame relays are innovative microprocessor based flame control relay for single burners units. They provide complete automation on the ignition and flame control of burner systems. They can be interfaced via a current loop to a computer or a PLC.

flame-monitoring-system-img11

Microscan Microprocessor Compact Control System

The MICROSCAN is a very compact PLC for the supervision and memorization of operation and safety switches of combustion equipment. They provide the usual functions: Alarm bypass / Alarm silence / Reset / Lamp test.

flame-monitoring-system-img12

Sens-A-Flame Electronic Flame Monitoring

The Sens-A-Flame is an electronic flame monitoring device that offers continuous surveillance of flames, detects the flame out, triggers a warning and shuts down the entire combustion system. It is designed for use with single or multiple burner installations. It includes many built-in features, solid state components for long life and plug-in modules for easy maintenance. They use ultraviolet or flame rod detectors.

flame-monitoring-system-img13

Pyronics Ultraviolet Scanners

The Pyronics UV Scanners are compact, reliable sensing units designed for use with the Sens-A-Flame. They are easy to install. They are built in weather resistant cast Aluminum enclosure.